Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int. j. cardiovasc. sci. (Impr.) ; 31(2): f:143-l:151, mar.-abr. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-882060

RESUMO

Background: Few studies have used portable gas analyzers during the 6-minute walk test (6MWT) in patients with heart failure and normal ejection fraction (HFNEF). Objectives: To analyze the kinetics of hemodynamic, ventilatory, and metabolic variables in patients with HFNEF during the T6m using a portable gas analyzer. Methods: Prospective, analytical study with an intentional, non-probabilistic, convenience sample. In total, 24 patients with HFNEF and past hospital admissions due to a clinical diagnosis of heart failure (HF) were included using the 2007 criteria established by the European Society of Cardiology. Three assessments were performed: 6MWT familiarization, 6MWT with the portable gas analyzer, and cardiopulmonary exercise test (CPET). Results: The heart rates (HRs) and the peak VO 2 at the end of the 6MWT corresponded to 85.7% and 86.45% of the values obtained during the CPET. The final HRs after the T6m were equivalent to those obtained at the CPET anaerobic threshold (AT), with relative VO 2 values at the end of the 6MWT above the VO 2 of the CPET AT. There was no difference between the maximum respiratory quotient (RQ) values in these two tests, which were both above 1.0. The VE/VO 2 slope descended initially and then ascended significantly after the fifth minute of the test, estimating the identification of the AT. Conclusions: In patients with HFNEF, the 6MWT represents an almost maximum effort, and is performed above the CPET AT and 85% above the maximum HR and the CPET peak VO 2 , with a maximum RQ similar to that in the CPET


Fundamentos: Poucos estudos utilizaram analisadores de gases portáteis no teste da caminhada de seis minutos (T6m) em portadores de insuficiência cardíaca com fração de ejeção normal (ICFEN). Objetivos: Analisar a cinética das variáveis hemodinâmicas, ventilatórias e metabólicas utilizando analisador de gases portátil em portadores de ICFEN durante o T6m. Métodos: Estudo prospectivo, analítico, com amostra não probabilística, intencional e por conveniência. Foram estudados 24 pacientes portadores de ICFEN com passado de internação por clínica de insuficiência cardíaca (IC), incluídos pelos critérios da European Society of Cardiology 2007. Realizaram-se três avaliações: T6m de aprendizado, T6m com o analisador de gases portátil e teste de esforço cardiopulmonar (TECP). Resultados: As frequências cardíacas (FC) e o consumo de oxigênio (VO 2 ) pico ao final do T6m corresponderam a 85,7% e 86,45% dos valores obtidos no TECP. As FC finais no T6m foram equivalentes às obtidas no limiar anaeróbio (LA) do TECP, com valores de VO 2 relativo ao final do T6m acima do VO 2 no LA do TECP. Não houve diferença entre os valores máximos do quociente respiratório (QR) entre os dois testes, ambos acima de 1,0. A curva de VE/VO 2 demonstrou descenso com posterior ascensão significativa após o quinto minuto de teste, estimando-se a identificação do LA. Conclusões: Para pacientes com ICFEN, o T6m representa um esforço quase máximo, sendo executado acima do LA do TECP e acima dos 85% da FC máxima e do VO 2 pico do TECP, com QR máximo semelhante ao do TECP


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Gasometria/métodos , Exercício Físico , Insuficiência Cardíaca , Volume Sistólico , Teste de Caminhada/métodos , Índice de Massa Corporal , Doença da Artéria Coronariana , Diabetes Mellitus , Dislipidemias , Hipertensão , Obesidade , Estudos Prospectivos , Fatores de Risco , Interpretação Estatística de Dados
2.
Conscientiae saúde (Impr.) ; 16(1): 20172632, 31 mar. 2017.
Artigo em Português | LILACS | ID: biblio-868435

RESUMO

Introdução: A força e a potência muscular têm relação direta com a capacidade funcional de idosos. Objetivo: Verificar o efeito absoluto e relativo da potência muscular de membros inferiores em idosos portadores de doença arterial coronariana. Métodos: Dez homens sedentários participaram de 24 sessões de treinamento de força compostas por 2 séries de 6 a 8 repetições máximas e 1 minuto de intervalo. No início, os exercícios foram: meio agachamento, step, flexão plantar. E após: extensão e flexão dos joelhos, adução e abdução do quadril sentado. A potência muscular foi mensurada nos momentos: pré, após 12 e 24 sessões. Resultados: Após 24 sessões de treinamento de força foram encontrados aumentos na potência muscular absoluta (p< 0.0001) e relativa (p<0.0001; p<0.0001) em relação à condição pré-treinamento, respectivamente. Conclusão: Vinte e quatro sessões de treinamento de força parecem ser suficientes para aumentar a PM absoluta e relativa de idosos coronariopatas. (AU)


Introduction: Strength and muscle power have a direct relationship with functional capacity in elderly people. Objective: Verify absolute and relative gains in muscle power of lower limbs in elderly people with coronary artery disease. Methods: Ten untrained men subjects participated of 24 sessions of resistance training composed by 2 sets of 6 to 8 maximum repetitions and 1 minute rest interval. Initially, the exercises were: half squat, step up and plantar flexion. And after: leg extension, leg curl, seated hip adduction and seated hip abduction. The muscle power was measured at times: pre, post 12 and 24 sessions. Results: After 24 sessions of resistance training were found increases in absolute muscle power (p< 0.0001) and relative (p< 0.0001) regarding the condition pre-training, respectively. Conclusion: Twenty four sessions of resistance training appear to be sufficient to increase absolute and relative muscle power in elderly people with coronary artery disease. (AU)


Assuntos
Humanos , Masculino , Idoso , Doença da Artéria Coronariana/reabilitação , Treinamento de Força , Extremidade Inferior , Força Muscular , Reabilitação Cardíaca/métodos
3.
Rev. bras. med. esporte ; 20(1): 41-46, Jan-Feb/2014. tab, graf
Artigo em Português | LILACS | ID: lil-704728

RESUMO

INTRODUÇÃO: O teste de esforço cardiopulmonar (TECP) fornece dados que orientam tratamento, prognóstico e tomadas de decisões. Entretanto, seu uso na insuficiência cardíaca de fração de ejeção normal (ICFEN) ainda não está bem esclarecido, em especial considerando novas variáveis que vêm despontando. OBJETIVOS: Comparar o comportamento das principais variáveis diagnósticas e prognósticas do TECP entre dois grupos: pacientes com insuficiência cardíaca de fração de ejeção reduzida (ICFER) e pacientes com ICFEN. MÉTODOS: Foram avaliados 36 pacientes com insuficiência cardíaca em classe funcional II-III da NYAH: 20 com ICFEN e 16 com ICFER do ambulatório de insuficiência cardíaca do Hospital Universitário Antônio Pedro (UFF). Os pacientes do Grupo ICFER selecionados foram os com FE < 35% e os do grupo ICFEN seguiram os critérios diagnósticos da Sociedade Europeia de Cardiologia de 2007. Realizou-se TECP, em esteira com protocolo de rampa, com analisador de gases VO2000. Foram aplicados teste t de Student, Mann-Whitney, teste de Fisher, modelo linear generalizado e de Cochran-Mantel-Haenszel para as análises estatísticas. RESULTADOS: O grupo ICFEN apresentou níveis mais elevados da pressão arterial em repouso, na resposta ao esforço, na potência circulatória e ventilatória, além de um maior tempo de recuperação da cinética do consumo de oxigênio. Não houve diferença em relação a outras variáveis prognósticas do TECP para o grupo ICFER. CONCLUSÕES: A pressão arterial de repouso e em esforço, a potência circulatória e ventilatória e a cinética de recuperação do VO2 (T1/2) foram as variáveis que apresentaram maior ...


INTRODUCTION: The cardiopulmonary exercise testing (CPX) provides data that guide treatment, prognosis and decision making. However its use in heart failure with normal ejection fraction (HFnEF) is still not all clear, especially considering new variables that are emerging. OBJECTIVE: To compare the behavior of key diagnostic and prognostic variables of CPX testing between two groups; patients with heart with reduced ejection fraction of (HfrEF) and those with HFnEF). METHODS: 36 patients with heart failure were evaluated in Nyah functional class II-III: 20 with HFnEF and 16 patients with HFrEF at the Hospital Universitário Antônio Pedro (UFF). The patients from HFrEF group were those with EF<35%, and those from the HFnEF group follow the diagnostic criteria of the European Society of Cardiology 2007. CPX was performed on a treadmill with a ramp protocol, with gas analyzer VO2000. The Student t test, Mann-Whitney test and Fisher, generalized linear model and the Cochran-Mantel-Haenszel test for statistical analysis were applied. RESULTS: The HFnEF group presented higher levels of blood pressure at rest, higher response to exertion, higher circulatory and ventilatory power, and longer recovery kinetics of oxygen uptake. There was no difference in relation to other prognostic variables of CPX in the HFrEF group. CONCLUSIONS: The blood pressure at rest and during exercise, the circulatory and ventilatory capacity and the kinetics of VO2 (T1/2), were the variables that showed the highest discriminative value between the two populations by CPX. .


INTRODUCCIÓN: La prueba de esfuerzo cardiopulmonar (PECP) suministra datos que orientan tratamiento, pronóstico y tomas de decisiones. No obstante, su uso en la insuficiencia cardíaca de fracción de eyección normal (ICFEN) todavía no está bien aclarado, en especial, considerando nuevas variables que vienen apareciendo. OBJETIVOS: Comparar el comportamiento de las variables principales de diagnóstico y de pronóstico de la PECP, entre dos grupos: pacientes con insuficiencia cardíaca de fracción de eyección reducida (ICFER) y pacientes con ICFEN. MÉTODOS: Se evaluaron 36 pacientes con insuficiencia cardíaca en clase funcional II-III de la NYAH: 20 con ICFEN y 16 con ICFER del dispensario de insuficiencia cardíaca del Hospital Universitário Antonio Pedro (UFF). Los pacientes del grupo ICFER fueron seleccionados con FE <35% y el grupo ICFEN siguieron los diagnósticos de la Sociedad Europea de Cardiología 2007 criterios. Se realizó la PECP, en estera con regulador de rampa, con analizador de gases VO2000. Se aplicaron las pruebas t de Student, Mann-Whitney, prueba de Fisher, modelo linear generalizado y de Cochran-Mantel-Haenszel para los análisis estadísticos. RESULTADOS: El grupo ICFEN presentó niveles más altos de presión arterial en reposo, en la respuesta al esfuerzo, en las potencias circulatoria y ventilatoria, además de un tempo más prolongado de recuperación de la cinética del consumo de oxígeno. No hubo diferencia en relación con otras variables de pronóstico de la PECP para el grupo ICFER. CONCLUSIONES: La presión arterial de reposo y en esfuerzo, las potencias circulatoria y ventilatoria y la cinética de recuperación del VO2 (T1/2) fueron las variables que presentaron más valor discriminativo entre los grupos según la PECP. .

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...